What You Need To Know About Fire Escape Stairs Regulations in the UK

Commercial businesses are required by law to have a whole host of fire safety processes and procedures in place. 

In the unfortunate event that a fire does break out at your premises, a swift and safe evacuation is essential to preserve property and save lives. 

If appropriate fire exits are not in place, then the risk to you and your staff is increased exponentially. With this in mind, it’s vital that you have the most suitable fire exits in place, and this includes fire escape stairs.  

Fire escape stairs are common and necessary on a whole host of buildings, particularly high-rise residential properties. 

In this article, the team here at IKT Consulting will take a closer look at external fire escape stairs regulations in the UK, providing you with all of the information you need.

 

What Are Fire Escape Stairs?

Before we explain the various staircase fire regulations in the UK, it’s important to fully understand what fire escape stairs actually are.

While most people are familiar with traditional fire escapes which are usually just doors that lead people outside, fire escape stairs are slightly less common. 

If a fire breaks out in a building that has multiple floors, it can sometimes be difficult for people to safely evacuate – especially if they’re located at a higher level. Fire escape stairs take the form of a staircase that is located on a building’s exterior, leading people down to a street level as part of a safe and effective evacuation process.  

These fire escape stairs are usually found on high-rise residential buildings and large commercial offices. 

 

Fire Escape Stairs Regulations In The UK

If you own or manage a large or high building of any type, it is essential you have the appropriate fire exits and fire safety equipment installed. In many cases, this will take the form of fire escape stairs. 

There is a wide range of fire escape stairs regulations in the UK that you need to be aware of, and in this section, we will take a look at some of the main basic things you must have in place with this equipment. 

Fire escape stairs must be clearly marked and easily accessible for everyone who may need to use them. It’s important that occupants have a safe means of escape and in practice, this means the fire escape stair doors should never be obstructed.  

UK regulations also stipulate that all of the materials used in the construction of fire escape stairs must be made from fire-resistant materials that can withstand high temperatures and extreme conditions. 

Every external fire escape staircase must meet the following conditions:

  • All doors that lead to staircases must be made from fire-resistant materials (a minimum of E30) and should be fitted with a self-closing device.
  • Fire-resisting construction (a minimum of RE30) is needed for the building envelope that follows the following measurements: 1,800mm above and horizontally from the flights and landings of an external staircase, 9m vertically below and 1,100m above the top landing of the stair.
  • It’s also important that fire-resisting (a minimum of RE30) construction is in place for parts of buildings within 1,800mm of the escape route from the foot of the stair to a place of safety. This must be the case unless there are alternative escape routes from the foot of the external staircase.
  • Glazing in areas of fire-resisting construction should be fixed shut and be fire-resisting (a minimum of E30).

As well as the type of materials used to construct fire escape staircases, it’s also important that the staircase meets specific design regulations. This includes, being sufficiently wide to allow people to evacuate as quickly as possible and having handrails in place that people can use as they leave the building. They also need to be properly lit so people can see where they are going.  

 

Who Is Responsible For Fire Escape Stairs?

Since coming into force, The Regulatory Reform (Fire Safety) Order 2005 outlines that the person responsible for commercial fire safety within the organisation is the individual who is deemed ‘responsible.’

This is the person that is considered to be in control of the building, and so is usually the owner or property manager depending on the structure of your organisation. If you are someone who owns or manages a business that is located in non-domestic premises, you will be the person who needs to ensure that all fire escape stairs are maintained, and the UK regulations are properly followed.

 

How Many Fire Escape Staircases Do I Need?

While there aren’t any specific rules to say how many external fire exits and fire staircases, are required in a commercial building, it is generally accepted that there needs to be more than one. It can be a combination of traditional fire exits and fire escape staircases, but ensuring more than one is present is important in case one becomes blocked or unusable during an emergency situation. 

Height is also something to consider, as it is recommended that residential buildings that are between 18m and 30m in height have at least two fire escape stairs installed.   

 

How To Make Sure Fire Escape Stairs Comply 

The best way to ensure that you’re complying with the necessary external fire escape stairs regulations in the UK is to ensure frequent maintenance occurs. 

Once a year, fire escapes should be inspected to check no problems have occurred, but at least every five years a more in-depth inspection needs to take place by a qualified structural engineer. 

Here at IKT Consulting, we offer leading external staircase inspections that will comprehensively review your fire escape staircase and provide recommendations based on whether any repairs are required.

To find out more, contact our team today.

Posted on Google Google
Amy Lonergan profile picture
Amy Lonergan
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Daniel came to visit our property due to some internal cracking we had noted. He was polite, friendly and extremely knowledgeable. A full report was recieved less than 10 days after the initial visit with detailed recommendations to ensure any issues are rectified. I would 100 percent recommend and look forward to working with Daniel again when we build our extension 😀 Many thanks!
Posted on Google Google
andrew Buxton profile picture
andrew Buxton
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I required a company to carry out structural surveys on a customer's external fire escapes. I contacted IKT Consulting LTD to carry out the surveys on my behalf. I found IKT Consulting Ltd to be very professional with an outstanding attitude towards customer service. The reports were very thorough and I would have no hesitation in using IKT Consulting LTD for future projects.
Posted on Google Google
victoria evans profile picture
victoria evans
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Daniel has been great from start to finish the multiple times we have used him. We run a small construction company and are always in need of a good engineer we can trust and is reliable. Daniel always returns calls if he is not available at the time and has a wealth of knowledge that is always extremely helpful. I would highly recommend
Posted on Google Google
S Hussain profile picture
S Hussain
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We recently purchased our house in Derby and required a steel beam calculation in January 24. During his visit to our house, he gave great alternative options for our kitchen/dining room design which resulted in us being able to maximise our space and natural light. Daniel Ikotun at IKT was extremely helpful, accommodating, professional and provided a very fast turnaround. Very good value and expert advice. Thanks again Daniel, would recommend your services to anyone looking for structural engineering support.
Posted on Google Google
Craig Pearce profile picture
Craig Pearce
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great experience with IKT Consulting Engineers LTD! From start to finish, they demonstrated unparalleled professionalism, expertise, and dedication to our project. If you're in need of top-notch structural engineering services, look no further than IKT Consulting Engineers LTD. They are truly the best in the business, and I cannot recommend them highly enough!
Posted on Google Google
Garry Saunders profile picture
Garry Saunders
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Daniel has gone above and beyond on my project and was extremely helpful throughout. I couldn’t have asked for more.
Posted on Google Google
David Swinscoe profile picture
David Swinscoe
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
As a company, we have engaged with IKT Consulting LTD several times for our structural survey requirements. We commend Marie and the entire company for their prompt service, reliability, and meticulous attention to detail. Our ongoing commitment to using IKT Consulting LTD is a testament to their consistent service
Posted on Google Google
Linzi Clark profile picture
Linzi Clark
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We are in the process of buying a house and had several structural issues flagged on the home buyers survey and was advised to have specific structural survey undertaken. I came across IKT Consulting online and decided to instruct them to undertake the survey. The engineer, Daniel, kindly offered to chat things through with me before the survey, gave me a call after the survey to give me the results, issued the report promptly, and then agreed to chat through the report with me after I'd had time to digest it. His explanations were super clear, jargon free, and really put my mind at ease about the necessary works. I really can't fault IKT Consulting - so glad I found them.
Posted on Google Google
Ruth C profile picture
Ruth C
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I recently purchased a house and decided to remove x2 chimney breasts in upstairs bedroom and downstairs kitchen diner. The builder went into the loft to inspect and discovered it was not safe to remove the chimney breast. The builder suggested getting a structural engineer to have a look and this is where IKT consulting was recommended to me. The company sent the relevant information and specifications to the builders to proceed with the work. The structural engineer also sent me the same information on what was to be done and explained the reasons why. This being my first home, I felt reassured as the engineer and I discussed the work in the loft. He was clear, concise and his knowledge was truly informative giving me great confidence in the company. Throughout the job, the engineer was consistent keeping on top of what was going on and liaised with the builders as well as myself. As an outcome, I received a completion document from the company. I was amazed from start to finish with how efficient, precise and organised the structural engineer was especially his communication between myself and builder. I would highly recommend IKT and will use again myself if needed. Thank you IKT Consulting!
Posted on Google Google
Catherine Jeynes profile picture
Catherine Jeynes
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I asked Daniel to assess the structural safety of a previous internal wall removal after cracks appeared in the wall on the floor above it. Before he came he gave clear advice about what areas needed to be exposed in order to be able to carry out his assessment and while he was carrying out his assessment he even gave me some advice about other structural issues around my home. He was friendly and professional throughout and I was really struck by how much he cared about the safety of the homes of those he visits. He prepared the report very quickly after the assessment (even though it was over the Christmas holidays) and when I had follow up questions he gave prompt and clear responses. I have been so impressed with his work ethic and his knowledge and intend to ask him back to sign off the work once it has been completed.
Mezzanine Structural Design

Mezzanine Structural Design

Teal Park, Netherfield

Structural Alterations

Structural Alterations

London Road, Derby

Residential Structural Design

Residential Structural Design

Guilford Street, Nottingham

Loft Conversion

Loft Conversion

Beeston, Nottingham

Some Of Our Clients

ipsum-uk-logo
KS-Connexions-Logo
Redhill-Academy-Trust_logo
SGS_logo

Questions?

Get in touch with our expert team today

Get in touch
Top